Onan generator · 6 model lines

Onan generator code 1

Most Onan documentation lists 1 as “Engine Over Temperature”. Some model lines word it differently or give it a different meaning: QG 2800i / 2500i LP (HGLAA Spec A-B) (“High Engine Temperature”); QG 7000i DF (HGLCA Spec A) (“Engine Temperature Exceeded Limit”).

Check your model first. The same code can mean different things on different models. Find the model number on the appliance's data label, then use the matching row below.

What code 1 means by model

Model lineWhat the manufacturer saysSource
QG 2800i / 2500i LP (HGLAA Spec A-B)The Cummins Onan QG 2800i/2500i LP HGLAA operator manuals list Code 1 as High Engine Temperature.Cummins Onan RV Generator Manuals
Cummins Onan QG 2800i/2500i LP HGLAA Spec A Operator Manual A062Y985
Cummins Onan QG 2800i/2500i LP HGLAA Spec B Operator Manual A075S349
QG 2800 / 2800 EVAP KV and QG 2500 LP KVThe Cummins Onan QG 2800 KV operator manual says one blink indicates shutdown due to high engine coolant temperature.Cummins Onan RV Generator Manuals
Cummins Onan QG 2800/2800 EVAP KV Spec E-M Operator Manual 981-0153
QG 7000i DF (HGLCA Spec A)The Cummins Onan QG 7000i DF HGLCA operator manual list Code 1 as Engine Temperature Exceeded Limit.Cummins Onan RV Generator Manuals
Cummins Onan QG 7000i DF HGLCA Spec A Operator Manual A079E225
Quiet Diesel 5000 (HDKBA)The Cummins Onan Quiet Diesel 5000 HDKBA operator manual lists Code 1 as Engine Over Temperature.Cummins Onan RV Generator Manuals
Cummins Onan Quiet Diesel 5000 HDKBA Operator Manual 0981-0166
Quiet Diesel 6000 / 7500 / 8000 (HDKAH, HDKAJ, HDKAK)The Cummins Onan Quiet Diesel 6000/7500/8000 HDKAH/HDKAJ/HDKAK operator manual lists Code 1 as Engine Over Temperature.Cummins Onan RV Generator Manuals
Cummins Onan Quiet Diesel 6000/7500/8000 HDKAH/HDKAJ/HDKAK Operator Manual A046L053
Quiet Diesel 10000 / 12500 (HDKCA, HDKCB)The Cummins Onan Quiet Diesel 10000/12500 HDKCA/HDKCB operator manual lists Code 1 as Engine Over Temperature.Cummins Onan RV Generator Manuals
Cummins Onan Quiet Diesel 10000/12500 HDKCA/HDKCB Operator Manual A043D713

What you can safely check

  • Stop the generator and let it cool.
  • Check oil level only with the unit off and cool.
  • Check only exterior intake or discharge blockage from normal access points.
  • Shut the generator down and let it cool.
  • Check only visible cooling-air openings for blockage before calling service if the fault repeats.
  • Check only coolant level and exterior air inlet/outlet blockage if the manual allows safe owner access.
  • Reduce loads before any safe restart.

Stop and call a technician for

  • Internal generator electrical output, inverter, controller, sensors, fuel system, ignition, AC circuit, and engine diagnosis belongs to Cummins service or a qualified generator technician.
  • Electrical output, inverter, controller, stator, rotor, fuel injection, sensors, wiring, coolant-system service, fuel leaks, and generator compartment repairs belong to Cummins service or a qualified generator technician.

Generators can produce carbon monoxide, hot surfaces, fuel hazards, moving-part hazards, and lethal voltage. Shut the generator down and do not open energized compartments unless qualified.

Write this down before you call

  • generator model/spec letter
  • hour meter
  • fault blink count
  • loads running when the shutdown occurred

Full code tables for these models

Related troubleshooting guides

Official sources