Norcold ยท 18 codes

Norcold N62, N64, N82 and N84 refrigerator fault codes

Every fault code, display message, and status light listed in Norcold's manuals for Norcold N62X / N82X; Norcold N64X / N84X; Norcold N62 / N64 / N82 / N84 (all). Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

N62X, N62XXX, N82X, N82XXX, N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, N84XIMXX

Where to look and what to record

  • model and serial label
  • photo of display or light pattern
  • power mode and audible alarm state

Code table

CodeWhat the manufacturer saysListed for
no displayDC voltage is unavailable to the control panel or the refrigerator is offNorcold N62 / N64 / N82 / N84 (all)
dThe door has been open for more than two minutesNorcold N62X / N82X
FLP ignition or re-ignition failedNorcold N62X / N82X
AAC voltage is unavailable to the refrigerator control panelNorcold N62X / N82X
CDC voltage to the refrigerator control panel is too lowNorcold N62X / N82X
temperature number flashesThe refrigerator is operating on the backup operating systemNorcold N62 / N64 / N82 / N84 (all)
HA fault exists within the refrigerator controlsNorcold N62X / N82X
rA fault exists within the refrigerator controlsNorcold N62X / N82X
SA fault exists within the refrigerator controlsNorcold N62X / N82X
drThe door has been open for more than two minutes and an audible alarm is also presentNorcold N64X / N84X
no FLLP ignition or re-ignition failed and an audible alarm is also presentNorcold N64X / N84X
no ACAC voltage is unavailable to the refrigerator control panel and an audible alarm is also presentNorcold N64X / N84X
dc LODC voltage to the refrigerator control panel is too low and an audible alarm is also presentNorcold N64X / N84X
AC rEA fault exists within the refrigerator controls and an audible alarm is also presentNorcold N64X / N84X
dc rEA fault exists within the refrigerator controls and an audible alarm is also presentNorcold N64X / N84X
AC HEA fault exists within the refrigerator controls and an audible alarm is also presentNorcold N64X / N84X
dc HEA fault exists within the refrigerator controls and an audible alarm is also presentNorcold N64X / N84X
SrA fault exists within the refrigerator controls and an audible alarm is also presentNorcold N64X / N84X

Do not hand-light, clean flame parts, adjust LP gas, bypass refrigerator controls, or open electrical compartments. Shut off LP if gas odor is present and arrange qualified Norcold service for unresolved faults.