Furrion refrigerator · 1 model line
Furrion refrigerator: diagnostic LED flash 6
The Furrion Arctic refrigerator troubleshooting manual maps diagnostic LED flash 6 to Controller Hardware Fault: the controller detects abnormal parameters.
What this message means by model
| Model line | What the manufacturer says | Source |
|---|---|---|
| Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) | The Furrion Arctic refrigerator troubleshooting manual maps diagnostic LED flash 6 to Controller Hardware Fault: the controller detects abnormal parameters. | Furrion Arctic 8 and 10 Cu. Ft. Refrigerator Troubleshooting and Service Manual |
What you can safely check
- Turn the refrigerator off.
- Record the flash count for Furrion service.
Stop and call a technician for
- Diagnostic LED setup, inverter PCB access, fan current checks, compressor checks, wiring diagnostics, board replacement, and sealed-system service are qualified service work.
Disconnect power before refrigerator service. Do not open rear electrical compartments, inverter PCB wiring, compressor wiring, or refrigerant systems unless qualified.
Write this down before you call
- refrigerator model
- flash count
- battery voltage from installed monitor
- ventilation clearance
- cooling behavior
Other codes on Furrion RV refrigerators
Full table: Furrion RV refrigerators
- E1 Voltage on compressor is too low or too high
- E12 Compressor inverter hardware failure
- E13 Temperature sensor in refrigerator compartment is defective
- E14 Temperature sensor in freezer compartment is defective
- E2 Fan inside freezer compartment is defective / Fridge sensor failure
- E3 Compressor motor is stuck or system pressure is too high / Freezer sensor failure
- E4 Compressor runs with the wrong speed / Frosting sensor failure
- E5 Compressor inverter is too hot / Compressor start failure
- EH Input voltage to refrigerator is too high above 17 V
- EL Input voltage to refrigerator is low between 9.1 V and 10.6 V
- CS Sensor failure in the drinks box
- ES Failure of ambient temperature sensor
- Fd Defrosting sensor failure
- FF Fan failure
- FS Sensor failure in the freezing chamber
- RS Sensor failure in the refrigerating chamber
- UC Communication failure or model mismatch
- diagnostic LED flash 1 Voltage Fault: the input voltage is beyond normal parameters.
- diagnostic LED flash 2 Fan Fault Current: the fan's output current is more than 1 A peak.
- diagnostic LED flash 3 Compressor Start Fault: the rotor is blocked or system pressure is too high.
- diagnostic LED flash 4 Minimum Motor Speed Error: the compressor motor cannot maintain minimum 1850 RPM due to h…
- diagnostic LED flash 5 Thermal Fault: the system shut down due to high temperature from ambient conditions or th…
- E0 Door alarm because the fridge door has been open more than 5 minutes
- E1 OV ALM E1 with OV ALM icon: over-voltage alarm
- E1 UV ALM E1 with UV ALM icon: low-voltage alarm
- E6 Ambient temperature sensor failure
- EC Communication failure
- EF Fan failure