Furrion ยท 29 codes
Furrion RV refrigerator fault codes
Every fault code, display message, and status light listed in Furrion's manuals for Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA); Furrion 15 cu. ft. built-in (FCR16ACGFA); Furrion Arctic 8 / 10 cu. ft. (diagnostic LED). Select a code for what it means, what you can safely check, and when to call a technician.
Confirm your model
Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:
FCR11DCGTA-BG-LHH, FCR11DCGTA-BG-RHH, FCR11DCGTA-SG-LHH, FCR11DCGTA-SG-RHH, FCR10DCGFA-SG, FCR10DCGFA-BG, FCR16ACGFA-BG, Arctic 8 cu. ft. refrigerator, Arctic 10 cu. ft. refrigerator
Where to look and what to record
- refrigerator model
- displayed code
- battery/shore-power state
- door state
- ventilation clearance
- flash count
- battery voltage from installed monitor
- cooling behavior
Code table
| Code | What the manufacturer says | Listed for |
|---|---|---|
| E1 | Voltage on compressor is too low or too high | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| E12 | Compressor inverter hardware failure | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| E13 | Temperature sensor in refrigerator compartment is defective | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| E14 | Temperature sensor in freezer compartment is defective | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| E2 | Fan inside freezer compartment is defective / Fridge sensor failure | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E3 | Compressor motor is stuck or system pressure is too high / Freezer sensor failure | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E4 | Compressor runs with the wrong speed / Frosting sensor failure | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E5 | Compressor inverter is too hot / Compressor start failure | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| EH | Input voltage to refrigerator is too high above 17 V | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| EL | Input voltage to refrigerator is low between 9.1 V and 10.6 V | Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA) |
| CS | Sensor failure in the drinks box | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| ES | Failure of ambient temperature sensor | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| Fd | Defrosting sensor failure | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| FF | Fan failure | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| FS | Sensor failure in the freezing chamber | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| RS | Sensor failure in the refrigerating chamber | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| UC | Communication failure or model mismatch | Furrion 15 cu. ft. built-in (FCR16ACGFA) |
| diagnostic LED flash 1 | Voltage Fault: the input voltage is beyond normal parameters. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| diagnostic LED flash 2 | Fan Fault Current: the fan's output current is more than 1 A peak. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| diagnostic LED flash 3 | Compressor Start Fault: the rotor is blocked or system pressure is too high. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| diagnostic LED flash 4 | Minimum Motor Speed Error: the compressor motor cannot maintain minimum 1850 RPM due to heavy load on the compressor. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| diagnostic LED flash 5 | Thermal Fault: the system shut down due to high temperature from ambient conditions or the system working too hard. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| diagnostic LED flash 6 | Controller Hardware Fault: the controller detects abnormal parameters. | Furrion Arctic 8 / 10 cu. ft. (diagnostic LED) |
| E0 | Door alarm because the fridge door has been open more than 5 minutes | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E1 OV ALM | E1 with OV ALM icon: over-voltage alarm | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E1 UV ALM | E1 with UV ALM icon: low-voltage alarm | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| E6 | Ambient temperature sensor failure | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| EC | Communication failure | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
| EF | Fan failure | Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA) |
Disconnect power before refrigerator service. Do not open electrical compartments, compressor wiring, inverter wiring, fans, sensors, or refrigerant systems unless qualified.
Troubleshooting guides
- Furrion refrigerator door seal or door not closing
- Furrion refrigerator moisture, ice, condensation, or defrost
- Furrion refrigerator normal noises, vibration, or rattling
- Furrion refrigerator not cold enough, seals, vents, or temperature
- Furrion refrigerator temperature mode, lock mode, or off-grid setting
- Furrion 12V refrigerator compressor cycling, low battery, or heat
- Furrion 12V refrigerator no power, service line, or reset
- Furrion refrigerator service-only compressor, sensor, wiring, or refrigerant boundary
- RV appliance low-voltage warning
- RV refrigerator is not cooling