Furrion ยท 29 codes

Furrion RV refrigerator fault codes

Every fault code, display message, and status light listed in Furrion's manuals for Furrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA); Furrion 15 cu. ft. built-in (FCR16ACGFA); Furrion Arctic 8 / 10 cu. ft. (diagnostic LED). Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

FCR11DCGTA-BG-LHH, FCR11DCGTA-BG-RHH, FCR11DCGTA-SG-LHH, FCR11DCGTA-SG-RHH, FCR10DCGFA-SG, FCR10DCGFA-BG, FCR16ACGFA-BG, Arctic 8 cu. ft. refrigerator, Arctic 10 cu. ft. refrigerator

Where to look and what to record

  • refrigerator model
  • displayed code
  • battery/shore-power state
  • door state
  • ventilation clearance
  • flash count
  • battery voltage from installed monitor
  • cooling behavior

Code table

CodeWhat the manufacturer saysListed for
E1Voltage on compressor is too low or too highFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
E12Compressor inverter hardware failureFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
E13Temperature sensor in refrigerator compartment is defectiveFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
E14Temperature sensor in freezer compartment is defectiveFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
E2Fan inside freezer compartment is defective / Fridge sensor failureFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E3Compressor motor is stuck or system pressure is too high / Freezer sensor failureFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E4Compressor runs with the wrong speed / Frosting sensor failureFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E5Compressor inverter is too hot / Compressor start failureFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA); Furrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
EHInput voltage to refrigerator is too high above 17 VFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
ELInput voltage to refrigerator is low between 9.1 V and 10.6 VFurrion Arctic 10.6 cu. ft. 12V (FCR11DCGTA)
CSSensor failure in the drinks boxFurrion 15 cu. ft. built-in (FCR16ACGFA)
ESFailure of ambient temperature sensorFurrion 15 cu. ft. built-in (FCR16ACGFA)
FdDefrosting sensor failureFurrion 15 cu. ft. built-in (FCR16ACGFA)
FFFan failureFurrion 15 cu. ft. built-in (FCR16ACGFA)
FSSensor failure in the freezing chamberFurrion 15 cu. ft. built-in (FCR16ACGFA)
RSSensor failure in the refrigerating chamberFurrion 15 cu. ft. built-in (FCR16ACGFA)
UCCommunication failure or model mismatchFurrion 15 cu. ft. built-in (FCR16ACGFA)
diagnostic LED flash 1Voltage Fault: the input voltage is beyond normal parameters.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
diagnostic LED flash 2Fan Fault Current: the fan's output current is more than 1 A peak.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
diagnostic LED flash 3Compressor Start Fault: the rotor is blocked or system pressure is too high.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
diagnostic LED flash 4Minimum Motor Speed Error: the compressor motor cannot maintain minimum 1850 RPM due to heavy load on the compressor.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
diagnostic LED flash 5Thermal Fault: the system shut down due to high temperature from ambient conditions or the system working too hard.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
diagnostic LED flash 6Controller Hardware Fault: the controller detects abnormal parameters.Furrion Arctic 8 / 10 cu. ft. (diagnostic LED)
E0Door alarm because the fridge door has been open more than 5 minutesFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E1 OV ALME1 with OV ALM icon: over-voltage alarmFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E1 UV ALME1 with UV ALM icon: low-voltage alarmFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
E6Ambient temperature sensor failureFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
ECCommunication failureFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)
EFFan failureFurrion Arctic 10.7 cu. ft. French door (FCR10DCGFA)

Disconnect power before refrigerator service. Do not open electrical compartments, compressor wiring, inverter wiring, fans, sensors, or refrigerant systems unless qualified.

Troubleshooting guides

Official manuals and support pages