Furrion rooftop air conditioner and thermostat fault codes

Every fault code, display message, and status light listed in Furrion's manuals for Furrion rooftop air conditioner (CCD-0005592); Furrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA); Furrion Chill Cube ducted single-zone thermostat (FACW13VSDSA / FACC13VSD). Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

Furrion rooftop air conditioner with wall thermostat/control box, FACW12ESPA-BL, FACC12ESPA-BL control box, FACW13VSDSA-BL, FACC13VSD

Where to look and what to record

  • thermostat model
  • control-box label
  • rooftop model
  • displayed code
  • air conditioner model
  • whether furnace-only mode still works

Code table

CodeWhat the manufacturer saysListed for
E1Indoor temperature sensor out of order; system will shut downFurrion rooftop air conditioner (CCD-0005592)
E2Evaporator temperature sensor out of order; system will shut downFurrion rooftop air conditioner (CCD-0005592)
E3Loss of communication between the thermostat and control box; system will shut downFurrion rooftop air conditioner (CCD-0005592)
E4Condenser temperature sensor out of order; system will shut downFurrion rooftop air conditioner (CCD-0005592)
E5Outdoor temperature sensor out of order; system will shut downFurrion rooftop air conditioner (CCD-0005592)
loInsufficient low level of +12 V power supply; system will shut downFurrion rooftop air conditioner (CCD-0005592)
E3Loss of communication between the thermostat and air conditioner; thermostat remains operable for gas furnace heating function / Loss of communication between the thermostat and control box; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA); Furrion Chill Cube ducted single-zone thermostat (FACW13VSDSA / FACC13VSD)
E6Thermostat indoor temperature sensor out of order; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA); Furrion Chill Cube ducted single-zone thermostat (FACW13VSDSA / FACC13VSD)
loInsufficient low level of +12 V power supply; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA); Furrion Chill Cube ducted single-zone thermostat (FACW13VSDSA / FACC13VSD)
E1Control box indoor temperature sensor out of order; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA)
E2Evaporator temperature sensor out of order; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA)
E4Outdoor coil sensor out of order; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA)
E5Outdoor ambient air temperature sensor out of order; system will shut downFurrion heat pump single-zone wall thermostat (FACW12ESPA / FACC12ESPA)

Disconnect power before HVAC service. Do not open rooftop, line-voltage, or control-box electrical compartments unless qualified.