Furrion ยท 12 codes

Furrion tankless water heater fault codes

Every fault code, display message, and status light listed in Furrion's manuals for Furrion F2GWH tankless water heater; Furrion 2.4 GPM tankless water heater (FWH09A). Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

F2GWH, Lippert PN 2022107551, FWH09A-AM, FWH09AFA, FWH09AFA-AM, FWH09AFA-AB

Where to look and what to record

  • water heater model
  • wall controller display
  • water flow state
  • LP supply status
  • F2GWH model label
  • user control panel code
  • displayed temperature
  • LP supply state

Code table

CodeWhat the manufacturer saysListed for
E0Water outlet temperature system fault / Water outlet temperature probe failureAll listed models
E1Flame sense during ignition / Ignition failure or accidental flame off during ignitionAll listed models
E2Detected fake flame signal / Flame sensing interrupted during normal operationAll listed models
E3Over temperature mechanical sensor faulty / ECO open before ignition or during normal operation, normally from outlet water over 140 FAll listed models
E4Water inlet temperature system fault / Water inlet temperature probe failureAll listed models
E5Air pressure; Lippert TI-514 clarifies E5 as a blower motor or air pressure switch circuit condition / Blower motor failureAll listed models
E6Temperature surge / Over temperature when outlet water exceeds 140 F for 3 secondsAll listed models
E7Solenoid valve fault / Linear valve failureAll listed models
E8Air pressure switch not detected before ignition or cut off during normal operationFurrion F2GWH tankless water heater
E9Flame sensed before ignitionFurrion F2GWH tankless water heater
EnSystem timer after the water heater ran longer than 20 minutesFurrion F2GWH tankless water heater
FdWinter-use mode or freeze protection; the unit runs briefly and shuts off in freezing conditions when LP and 12V power are onFurrion F2GWH tankless water heater

Do not run a gas water heater with abnormal flame, blocked venting, gas odor, or repeated lockout. Shut off LP/power and call service if the code persists.

Do not keep operating a tankless gas water heater with repeated display faults, abnormal heat, blocked exhaust, gas odor, or unstable hot-water temperature.

Do not leave a tankless gas water heater running unattended. Stop the water demand and investigate open fixtures or leaks before restarting.

Troubleshooting guides

Official manuals and support pages