Dometic ยท 19 codes
Dometic FreshJet Series 4 / Series 7 air conditioner fault codes
Every fault code, display message, and status light listed in Dometic's manuals for Dometic FreshJet Series 4 / Series 7 (FJX). Select a code for what it means, what you can safely check, and when to call a technician.
Confirm your model
Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:
FreshJet Series 4, FreshJet Series 7, FJX4333EEH, FJX7333IHP
Where to look and what to record
- Full FreshJet model and serial number from the data label
- Wall control or display code photo
- Shore-power or campsite voltage context and active loads
- Recent service history and prior recurring codes
Code table
| Code | What the manufacturer says |
|---|---|
| P0 | Over temperature or over current on the IPM module |
| P1 | Under voltage protection |
| P2 | Unit AC over-current protection |
| P3 | Overvoltage protection |
| P4 | Discharge tube overheat protection |
| P5 | Evaporator coil protection in cooling mode |
| P6 | Condenser coil protection in cooling mode |
| P7 | Evaporator coil protection in heating mode |
| P9 | Compressor drive abnormal or compressor does not start |
| E0 | Communication failure |
| E1 | Room temperature sensor fault |
| E2 | Evaporator coil temperature sensor fault |
| E3 | Condenser coil temperature sensor fault |
| E7 | Outdoor temperature sensor failure |
| E8 | Discharge tube temperature sensor failure |
| E9 | Compressor drive or IPM module fault |
| EA | Current sensor fault |
| EE | Outdoor EEPROM fault |
| EL | LIN-BUS/CI-BUS communication failure |
Disconnect power before any FreshJet service. Refrigerant-circuit, sealed-system, sensor, fan, drive, electrical protection, roof seal, and internal component work is for authorized Dometic service or qualified RV HVAC personnel.
Troubleshooting guides
- Dometic FreshJet FJX constantly switches itself off
- Dometic FreshJet FJX low air output
- Dometic FreshJet FJX not cooling within temperature limits
- Dometic FreshJet FJX not heating within temperature limits
- Dometic FreshJet FJX voltage protection and campsite power
- Dometic FreshJet FJX water enters the vehicle
- Dometic FreshJet not cooling mode selection
- Airflow, venting, or exhaust fault
- RV appliance low-voltage warning
- RV rooftop air conditioner is not cooling enough