Norcold ยท 12 codes

Norcold N10LX / NA10LX refrigerator fault codes

Every fault code, display message, and status light listed in Norcold's manuals for Norcold N10LX / NA10LX. Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

N10LX, NA10LX, N10LXIM, NA10LXIM

Where to look and what to record

  • model and serial label
  • photo of display code
  • power mode shown on display

Code table

CodeWhat the manufacturer says
no FLThe burner did not ignite or re-ignite
no ACAC voltage is not available to the refrigerator
AC HEThis fault indicates a problem relating to the AC heater
AC rEThis fault is within the refrigerator controls
Lo dcDC input voltage to the refrigerator is too low with an audible alarm
HI dcDC input voltage to the refrigerator is too high
no dtThis fault indicates a loss of communication between the refrigerator controls
SrThis fault is within the refrigerator electronic controls
oP LIThis fault is within the refrigerator electronic controls
FL --A flame is sensed at the burner when there should be none present
temperature setting flashesThe thermistor has been sensed as inoperable, so temperature is controlled via backup operating system
blank displayThe refrigerator is off or will not turn on

Do not hand-light, clean burner parts, adjust LP gas, bypass refrigerator controls, or open electrical compartments. Shut off LP if gas odor is present and arrange qualified Norcold service for unresolved faults.