Norcold ยท 10 codes

Norcold N8DCX / N10DCX refrigerator fault codes

Every fault code, display message, and status light listed in Norcold's manuals for Norcold N8DCX / N10DCX. Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

N8DCX, N10DCX

Where to look and what to record

  • model and serial label
  • photo of display or LED state
  • battery monitor reading if visible

Code table

CodeWhat the manufacturer says
E1The thermistor in the fresh food compartment is not cycling properly
E2The thermistor in the freezer compartment is not cycling properly
E3The voltage is outside the cut-out setting
E4The fresh food compartment door has been open for more than two minutes
power module flash 1Compressor Power Module Battery Protection Cut-Out; voltage is outside the compressor cut-out setting of 9.8-17.0 VDC
power module flash 2Fan Over Current Cut-Out; the load is more than 1.0 amp sensed on terminal F-
power module flash 3Compressor Motor Start Error; the rotor is blocked or differential pressure in the refrigeration system is too high
power module flash 4Minimum Compressor Motor Speed Error; the motor cannot maintain minimum speed
power module flash 5Thermal Cut-Out of Compressor Power Module; the compressor power module is running too hot
power module flash 6Compressor Power Module Hardware Failure

Do not bypass compressor controls, fan circuits, thermistors, fuse protection, or DC wiring. Shut off the refrigerator and arrange qualified Norcold service for unresolved diagnostic faults.

Troubleshooting guides

Official manuals and support pages