Onan generator · 2 model lines
Onan generator code 34
Onan documentation describes 34 separately for each model line: QG 2800i / 2500i LP (HGLAA Spec A-B) (“High Inverter Temperature”); QG 7000i DF (HGLCA Spec A) (“Inverter temperature Exceeded Limit”). Compare the wording for your model below.
Check your model first. The same code can mean different things on different models. Find the model number on the appliance's data label, then use the matching row below.
What code 34 means by model
| Model line | What the manufacturer says | Source |
|---|---|---|
| QG 2800i / 2500i LP (HGLAA Spec A-B) | The Cummins Onan QG 2800i/2500i LP HGLAA operator manuals list Code 34 as High Inverter Temperature. | Cummins Onan RV Generator Manuals Cummins Onan QG 2800i/2500i LP HGLAA Spec A Operator Manual A062Y985 Cummins Onan QG 2800i/2500i LP HGLAA Spec B Operator Manual A075S349 |
| QG 7000i DF (HGLCA Spec A) | The Cummins Onan QG 7000i DF HGLCA operator manual list Code 34 as Inverter temperature Exceeded Limit. | Cummins Onan RV Generator Manuals Cummins Onan QG 7000i DF HGLCA Spec A Operator Manual A079E225 |
What you can safely check
- Stop the generator and let it cool.
- Check oil level only with the unit off and cool.
- Check only exterior intake or discharge blockage from normal access points.
Stop and call a technician for
- Internal generator electrical output, inverter, controller, sensors, fuel system, ignition, AC circuit, and engine diagnosis belongs to Cummins service or a qualified generator technician.
Generators can produce carbon monoxide, hot surfaces, fuel hazards, moving-part hazards, and lethal voltage. Shut the generator down and do not open energized compartments unless qualified.
Write this down before you call
- generator model/spec
- hour meter
- fault blink count
- loads running when the shutdown occurred
Other codes on Cummins Onan QG 2800i / 2500i LP inverter generators
Full table: Cummins Onan QG 2800i / 2500i LP inverter generators
- 1 High Engine Temperature
- 4 Over Crank
- 6 Low Oil Level
- 12 Output Over Voltage
- 13 Output Under Voltage
- 14 Output Over Frequency
- 15 Output Under Frequency
- 19 Actuator Circuit Fault
- 25 Alternator Over Voltage
- 26 Alternator Under Voltage
- 27 PMA Sense Lost
- 29 Battery Over Voltage
- 31 Engine Over Speed
- 32 Crank Under Speed
- 35 EE Checksum Fault
- 36 Mechanical Fault
- 38 Output Over Load
- 43 RAM Fault
- 45 Crank Position Sense Lost
- 49 Actuator Over Load
- 52 Injector/Lift Pump Circuit Fault
- 53 Oil Temperature Sensor Circuit Fault
- 54 MAT Sensor Circuit Fault
- 56 MAP Sensor Circuit Fault
- 67 IGBT Over Current Fault
- 74 Unprogrammed Board
- 81 Alternator Stator Circuit Fault
- 82 Vent Pressure Sensor Circuit Fault
Other codes on Cummins Onan QG 7000i dual-fuel inverter generators
Full table: Cummins Onan QG 7000i dual-fuel inverter generators
- 1 Engine Temperature Exceeded Limit
- 4 Over Crank
- 6 Low Oil Pressure
- 12 Over Voltage
- 13 Under Voltage
- 14 Over Frequency
- 15 Under Frequency
- 19 Actuator Circuit Fault
- 25 Alternator Overvoltage
- 26 Alternator Undervoltage
- 27 PMA Sense Lost
- 29 High Battery Voltage
- 31 Over Speed
- 36 Other Faults
- 38 Over Current (Field Overload)
- 43 ECU Fault
- 45 Speed Sense
- 52 Fuel Injector or IPM Pump Circuit Fault
- 53 Oil Temperature Sensor Circuit Fault
- 54 MAT Sensor
- 57 Over Prime Or LPG Pressure Sensor Fault, The LPG Solenoid Valve Fault
- 73 AC Output Circuit Fault
- 81 Alternator Stator Circuit Fault
- 85 Oxygen Sensor Fault