Dometic ยท 19 codes

Dometic RMD8 refrigerator fault codes

Every fault code, display message, and status light listed in Dometic's manuals for Dometic RMD8xx1 / RMD8xx5; Dometic RMD8xx1 (internal battery models). Select a code for what it means, what you can safely check, and when to call a technician.

Confirm your model

Codes are model-specific. Match the model number on the appliance data label to one of these before using the table:

RMD8501, RMD8505, RMD8551, RMD8555, RMD8xx1, RMD8xx5

Where to look and what to record

  • Interior data label model, product number, serial number
  • Front display code or lamp state photo
  • Power module/display board part number if service requests it

Code table

CodeWhat the manufacturer saysListed for
AC plug + temperature bars flashing + 20 s beepThe AC heater element or cooling unit is defectiveDometic RMD8xx1 / RMD8xx5
DC battery + temperature bars flashing + 20 s beepThe DC heater element or cooling unit is defectiveDometic RMD8xx1 / RMD8xx5
gas flame + temperature bars flashing + 20 s beepThe burner or cooling unit is defectiveDometic RMD8xx1 / RMD8xx5
temperature bars flashingThe temperature sensor has no contact or is defectiveDometic RMD8xx1 / RMD8xx5
AC plug + warning triangle flashing + 20 s beepAC power supply is not available or insufficientDometic RMD8xx1 / RMD8xx5
DC battery + warning triangle flashing + 20 s beepDC power supply is not available or insufficientDometic RMD8xx1 / RMD8xx5
gas flame + warning triangle flashing + 20 s beepThe burner flame is not ignited during gas or automatic operationDometic RMD8xx1 / RMD8xx5
15 s beep every two minutesThe interior light is switched on / The interior lighting is switched onDometic RMD8xx1 / RMD8xx5
battery mode low-voltage 15 s beepIn battery operation, a signal every 15 seconds indicates low voltage detection in the internal battery / An acoustic signal at 15-second intervals indicates undervoltage detection in the internal batteriesDometic RMD8xx1 (internal battery models)
external-to-internal power switching failureExternal-to-internal power switching failure as: automatic change-over from external to internal power supply does not function, so the refrigerator does not work and gas mode is not possible even though batteries are inserted.Dometic RMD8xx1 (internal battery models)
2 + 8 flashing + 20 s beep230 V mode is not available or the voltage is too lowDometic RMD8xx1 / RMD8xx5
4 + 8 flashing + 20 s beep12 V mode is not available or the voltage is too low; AES models also call out the D+ signalDometic RMD8xx1 / RMD8xx5
3 + 8 flashing + 20 s beepGAS or automatic mode did not ignite the flameDometic RMD8xx1 / RMD8xx5
2 + 7 flashing + 20 s beepThe 230 V heating element is defectiveDometic RMD8xx1 / RMD8xx5
4 + 7 flashing + 20 s beepThe 12 V heating element is defectiveDometic RMD8xx1 / RMD8xx5
7 flashingThe temperature sensor has no contact or is defectiveDometic RMD8xx1 / RMD8xx5
3 + 7 flashing + 20 s beepThe burner or cooling unit is defectiveDometic RMD8xx1 / RMD8xx5
3 + 8 flashing brightlyDuring internal-battery operation, the flame was not ignitedDometic RMD8xx1 (internal battery models)
3 + 7 flashing brightlyDuring internal-battery operation, the burner or cooling unit is defectiveDometic RMD8xx1 (internal battery models)

Do not open gas, electrical, or cooling-system components; use only documented front-panel actions and call qualified RV service for repeated faults.