Lippert Red LED 5 fault code — Slide-out
Applies to: In-Wall Slide-out
What Red LED 5 means
The Lippert In-Wall Slide-out troubleshooting manual maps Red LED 5 to Excessive Motor Current: high amperage, also indicated by one side of the slide continually stalling.
Owner-safe checks
- Stop operating the slide.
- Keep people and objects clear of the slide room.
- Do not force the room if one side stalls.
Service-only work
- Controller reset, motor synchronization, encoder checks, wiring repair, motor service, and manual override should follow Lippert documentation or qualified service.
Safety boundary
Do not place hands or tools near moving slide mechanisms. Keep people clear and do not force the slide if current, short, or controller faults appear.