Norcold refrigerator · 6 model lines

Norcold refrigerator code no FL

Most Norcold documentation lists no FL as “The burner did not ignite or re-ignite”. Some model lines word it differently or give it a different meaning: Norcold N64X / N84X (“LP ignition or re-ignition failed and an audible alarm is also present”); Norcold N109X / N109XIM / N1095 (“LP ignition or re-ignition failed and an audible alarm is also present”).

Check your model first. The same code can mean different things on different models. Find the model number on the appliance's data label, then use the matching row below.

What code no FL means by model

Model lineWhat the manufacturer saysSource
Norcold 1200 seriesThe Norcold 1200 owner manual lists no FL as: The burner did not ignite or re-ignite.Norcold 1200 Series Owner's Manual
Norcold 2118 / 2118 PolarMaxThe Norcold 2118 owner manual lists no FL as: The burner did not ignite or re-ignite.Norcold 2118 PolarMax Owner's Manual
Norcold N109X / N109XIM / N1095The official N109X/N109XIM owner manual lists no FL as: LP ignition or re-ignition failed and an audible alarm is also present.Norcold N109X and N109XIM Owner's Manual
Norcold N10LX / NA10LXThe Norcold N10LX/NA10LX owner manual lists no FL as: The burner did not ignite or re-ignite.Norcold N10LX and NA10LX Owner's Manual
Norcold N64X / N84XThe official N64/N84 owner manual lists no FL as: LP ignition or re-ignition failed and an audible alarm is also present.Norcold N62/N64/N82/N84 Owner's Manual
Norcold Polar N7 / N8 (LX display)The Norcold Polar manual uses no FL for an LP flame/ignition failure condition.Norcold Polar N7/N8 Owner's Manual

What you can safely check

  • Record the exact display wording and whether an audible alarm is present.
  • Turn the refrigerator off if cooling is interrupted or the fault repeats.
  • Keep food safety in mind and move perishables if needed.
  • Move perishables if refrigerator temperature is unsafe.
  • Record the exact code and whether the fault happened in LP/manual gas or automatic mode.
  • Confirm LP is available using normal RV owner controls and shut LP off if any gas odor is present.
  • Switch the refrigerator off.
  • Make sure LP supply is not intentionally shut off before documenting the issue.
  • Record whether the code happens only on LP mode.

Stop and call a technician for

  • LP pressure, shutoff valve, burner, ignition, and gas-system diagnosis should be handled by qualified Norcold service if basic supply status is not the issue.
  • LP pressure, refrigerator LP shutoff, flame-sense, and ignition diagnosis should be handled by qualified Norcold service.
  • LP ignition, flame-sense, burner, gas valve, and board diagnosis requires qualified service.

Do not bypass high-temperature recall devices, refrigerator controls, LP components, or electrical circuits. Shut the refrigerator off and arrange qualified Norcold service for repeat or unsafe faults.

Do not hand-light, clean burner parts, adjust LP gas, bypass refrigerator controls, or open electrical compartments. Shut off LP if gas odor is present and arrange qualified Norcold service for unresolved faults.

Write this down before you call

  • model and serial label
  • display board code
  • power mode shown on display
  • photo of display code
  • photo of display or light pattern
  • power mode and audible alarm state
  • Norcold model label
  • LP regulator/service history