Lippert leveling system · 1 model line

Lippert leveling system: Left-Mid Jack Fault

Lippert documentation lists “Left-Mid Jack Fault” as “A left-middle jack hall signal, open-circuit, short-circuit, or communication problem”.

What this message means by model

Model lineWhat the manufacturer saysSource
Ground Control 5th wheel OneControl (4-point / 6-point)The Lippert Ground Control 5th Wheel OneControl owner manual lists Left-Mid Jack Fault as a left-middle jack hall signal, open-circuit, short-circuit, or communication problem.Lippert Ground Control 5th Wheel OneControl Touch Panel Owner's Manual

What you can safely check

  • Stop jack movement.
  • Keep people clear and record the affected jack.

Stop and call a technician for

  • Harness checks, fuse checks, controller placement, sensor placement, zero-point calibration, homing, jack service, and motor/controller repairs should be handled by a trained RV technician.

Never use leveling jacks as service stands. Keep people clear of jacks, pinch points, and trailer movement; do not service jack wiring, sensors, motors, or controllers unless qualified.

Write this down before you call

  • OneControl message
  • touchpad LED state
  • controller revision
  • affected jack position
  • battery voltage from installed monitor

Other codes on Lippert Ground Control leveling systems

Full table: Lippert Ground Control leveling systems

  • Auto Level Fail Auto level could not complete because of ground conditions or zero-point setup / An unsec…
  • BAD CALIBRATION Sensor calibration values are out of range / Trailer zero point was not set correctly
  • Comm Error Communication between controller and touchpad has been lost
  • EXCESS ANGLE Excessive angle reached during auto operation or an unsecured controller / An unsecured c…
  • EXCESSIVE ANGLE Excessive angle reached during manual operation or an unsecured controller
  • EXTERNAL SENSOR A bad connection or wiring from the controller to the rear sensor / Bad connection or wir…
  • FEATURE DISABLED Hitch recognition, touchpad power cycling, or zero-point setup preventing the feature / H…
  • FUNCTION ABORTED A button was pressed during automatic operation / An automatic leveling sequence was abor…
  • Hall Effect Short A short circuit detected in a hall-effect circuit
  • Internal Sensor An internal sensor problem
  • JACK TIME OUT The requested auto operation exceeded its time limit / The system could not level in the …
  • LF Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • LM Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • LOW VOLTAGE Battery voltage dropped below 10.8 V DC / Bad connection, wiring, discharged battery, or …
  • LR Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • Blinking Red A standard error that must be read on the OneControl Touch Panel or OneControl App
  • ***ERROR*** A special jack error screen requiring the specific affected jack message
  • HALL POWER SHORT A short circuit on one or more jack hall-effect power lines
  • Left-Front Jack Fault A left-front jack hall signal, open-circuit, short-circuit, or communication problem
  • Left-Rear Jack Fault A left-rear jack hall signal, open-circuit, short-circuit, or communication problem
  • OUT OF STROKE An unsecured controller or uneven/sloped site causing stroke limits / A jack reached maxi…
  • Right-Front Jack Fault A right-front jack hall signal, open-circuit, short-circuit, or communication problem
  • Right-Mid Jack Fault A right-middle jack hall signal, open-circuit, short-circuit, or communication problem
  • Right-Rear Jack Fault A right-rear jack hall signal, open-circuit, short-circuit, or communication problem
  • Slowly Blinking Faded Red A Rev
  • Solid Red Low battery on the auto leveling control touch pad
  • RF Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • RM Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • RR Jack A hall-signal, open-circuit, short-circuit, or communication problem at a specific jack
  • AUTO LEVEL FAILURE An unsecured controller or voltage drop during auto leveling
  • CAN'T COMPLETE LEVEL IN THIS LOCATION. PLEASE RELOCATE RV TO FLATTER TERRAIN The trailer is parked on a steep incline and the front cannot be leveled
  • Tongue Jack Fault A tongue jack hall signal, open-circuit, short-circuit, or communication problem

Related troubleshooting guides