Dometic refrigerator · 1 model line

Dometic refrigerator: Gas lock out, internal error in power module

The Dometic RM10 support page lists gas lock out caused by an internal power-module error and asks which controller is installed.

What this message means by model

Model lineWhat the manufacturer saysSource
Dometic RM10.5 / RMS10.5 (operating manual and RM10 fault support pages)The Dometic RM10 support page lists gas lock out caused by an internal power-module error and asks which controller is installed.Dometic RM10 Refrigerators Fault Gas Lock Out Internal Power Module Error Support

What you can safely check

  • Record whether the controller is LED display with touch control or TFT display with rotary knob.
  • Stop LP operation and use another normal energy mode if available and safe.
  • Call qualified service if the fault remains.

Stop and call a technician for

  • Power-module, ignition interlock, LP hardware, wiring, and refrigerator control diagnosis are service-only.

Do not service LP hardware, electrical circuits, wiring, or refrigerator controls; use only normal front-panel and owner-visible checks and call qualified service for repeated faults.

Write this down before you call

  • Interior data label model, product number, serial number
  • Front display code or lamp state photo
  • Power module/display board part number if service requests it

Other codes on Dometic RM10 / RMS10.5 refrigerators

Full table: Dometic RM10 / RMS10.5 refrigerators

  • Petrol pump symbol Tank stop mode, where gas operation is blocked for 15 minutes
  • 01 A temperature sensor that is without contact or defective; Dometic says this can only be …
  • 02 Display fault 02 and directs repair to an authorized service provider without giving an o…
  • 03 Display fault 03 and directs repair to an authorized service provider without giving an o…
  • 05 Which operation mode is selected for display fault 05: gas, 12 V DC from a battery, or 23…
  • 06 Display fault 06 and advises connecting the refrigerator to DC or selecting a different e…
  • 07 Display fault 07 and says to level the refrigerator, then press the control knob for 2 se…
  • 08 Display fault 08 and says to level the refrigerator, then press the control knob for 2 se…
  • 09 Display fault 09 and says to level the refrigerator, then press the control knob for 2 se…
  • 10 Display fault 10 and says to make sure the refrigerator door is completely closed, includ…
  • 11 Display fault 11 and says to reduce the DC supply voltage.
  • 12 Display fault 12 and says to press the control knob for 2 seconds to reset the error.
  • 13 Display fault 13 and says to press the control knob for 2 seconds to reset the error.
  • 14 Display fault 14 and says to insert new batteries, then press the control knob for 2 seco…
  • 50 Display fault 50 and says to replace an empty gas cylinder, press the control knob for 2 …
  • 51 Display fault 51 and says to press the control knob for 2 seconds to reset the error.
  • 52 Display fault 52 and says to press the control knob for 2 seconds to reset the error.
  • 53 Display fault 53 and says to press the control knob for 2 seconds to reset the error.
  • AC power not connected or AC voltage < 190 V AC power not connected or AC voltage below 190 V and asks which operating mode is selected
  • Beep: door opened more than 2 minutes A beep fault when the door has been opened for more than 2 minutes and says to make sure …
  • DC overvoltage > 16 V DC overvoltage above 16 V and says to reduce the DC supply voltage.
  • DC power not connected DC power not connected and advises connecting the refrigerator to DC or selecting a diffe…
  • Defective temperature sensor in refrigerator compartment This fault means the temperature sensor is without contact or defective and can only be r…
  • Gas lock out after 3 ignition attempts Gas lock out after 3 ignition attempts and asks whether the refrigerator is controlled by…
  • Gas valve check error A gas valve check error and asks whether the refrigerator is controlled by LED touch cont…
  • Ground contact, gas valve Ground contact at the gas valve and asks which controller is installed.
  • Ground contact, ignition electrode Ground contact at the ignition electrode and asks which controller is installed.
  • Stand-alone gas mode battery packs too low Stand-alone gas mode with battery-pack charge too low and asks which controller is instal…
  • Internal communication error An internal communication error and asks which controller is installed.
  • No connection between power module and display No connection between the power module and display can only be repaired by an authorized …
  • No cooling capacity in gas mode No cooling capacity in gas mode and asks which controller is installed.
  • No cooling power in AC mode No cooling power in AC mode and asks which controller is installed.
  • No cooling power in DC mode No cooling power in DC mode and asks which controller is installed.
  • Tank stop mode: gas operation blocked 15 minutes Tank stop mode where gas operation is blocked for 15 minutes and says to wait 15 minutes …
  • W01 Defective temperature sensor in the refrigerator compartment
  • W05 AC power is not connected or AC voltage is below the manual threshold
  • W06 DC power is not connected
  • W11 DC overvoltage is present
  • Beep Tank stop mode is active and gas operation is blocked for 15 minutes
  • W10 + beep The door has been open for more than two minutes
  • E03 There is no connection between power module and display
  • E07 There is no cooling capacity in gas mode
  • E08 There is no cooling power in AC mode
  • E09 There is no cooling power in DC mode
  • E12 Gas valve test error; gas operation is not possible
  • E13 Internal communication error; gas operation is not possible
  • E14 In stand-alone gas mode, the battery pack charge is too low
  • E50 Gas lock after three ignition attempts; ignition is not possible
  • E51 Gas lock caused by an internal power-module error
  • E52 Ground contact at the gas valve is detected
  • E53 Ground contact at the ignition electrode is detected

Related troubleshooting guides