Lippert water heater · 1 model line

Lippert water heater code Fd

The Lippert Girard GSWH-2 owner manual lists Fd as winter-use mode or freeze protection; the unit may run briefly and shut off in freezing conditions when LP gas and 12V power are on, but this protects only the water-heater heat exchanger and not the RV plumbing system.

What code Fd means by model

Model lineWhat the manufacturer saysSource
Girard GSWH-2The Lippert Girard GSWH-2 owner manual lists Fd as winter-use mode or freeze protection; the unit may run briefly and shut off in freezing conditions when LP gas and 12V power are on, but this protects only the water-heater heat exchanger and not the RV plumbing system.Lippert Girard GSWH-2 Tankless Water Heater Owner's Manual CCD-0006120

What you can safely check

  • Do not rely on Fd or winter-use mode to winterize the whole RV plumbing system.
  • Verify winterization history and shut water off if leaks or freeze damage are suspected.
  • Record the code, temperature, LP and 12V status, and any visible leaks.
  • Contact Lippert/Girard or a qualified technician before operating a suspected freeze-damaged heater.

Stop and call a technician for

  • Internal sensor, ignition, flame-sense, ECO, blower, pressure-switch, linear-valve, wiring, gas, and controller diagnosis is qualified service work.

The Girard GSWH-2 is an LP gas tankless water heater. Shut the heater off for gas odor, overheating, leaks, blocked exhaust, or repeated faults and use Lippert/Girard or qualified RV service.

Write this down before you call

  • Girard GSWH-2 model label
  • user control panel code
  • set and displayed temperature
  • water-flow state
  • LP and 12V status

Other codes on Lippert Girard tankless water heaters

Full table: Lippert Girard tankless water heaters

  • E0 Water outlet temperature probe failure
  • E1 Ignition failure or accidental flame off during ignition
  • E2 Flame sensing interrupted during normal operation and the buzzer will sound
  • E3 ECO open before ignition or during normal operation, commonly from outlet water temperatu…
  • E4 Water inlet temperature probe failure
  • E5 Blower motor failure because no motor signal was detected before ignition or during opera…
  • E6 Over temperature because outlet water temperature exceeded 140 F for 3 seconds
  • E7 Linear valve failure detected in the control circuit before ignition or during operation
  • E8 Air pressure switch not detected before ignition or cut off during normal operation
  • E9 Flame sensor error because flame is sensed before ignition and the buzzer will sound
  • En System timer because the water heater ran longer than 20 minutes
  • steady on Internal control fault
  • 1 flash Air fault
  • 2 flashes Flame detection error
  • 3 flashes Lockout
  • 4 flashes Intentionally NA and reserved for future diagnostics
  • 5 flashes Low voltage

Related troubleshooting guides

Official sources